Remise en service de la chambre

Pedestals

Tres bruyants.. ?

Coupure a 520 minimale !!!

L'humidite remonte doucement (43 % / 38 % au bout d'1/2 h)

J'avais oublie de recharge la version FE1_24CH_2

Piedestaux ok run 738816 ( coupure a 485 devrait etre ok )

En fait tre peu de bruit a Vth > 480

Cosmics

Vth> 480

1514977394.22058706700.0000005.0000006699.4000000.2500005.00000050.000000
1514977409.87174616700.0000005.0000006699.0000000.5000005.00000050.000000
1514978107.28438307000.0000005.0000006999.2000000.4000005.00000050.000000
1514978128.29183517000.0000005.0000006999.0000000.7500005.00000050.000000
1514984712.20359407000.0000005.0000006999.2000000.4000005.00000050.000000
1514984715.67845117000.0000005.0000006999.0000000.8500005.00000050.000000
1514984821.51621707100.0000005.0000007099.2000000.5500005.00000050.000000
1514984833.23762217100.0000005.0000007099.0000000.9500005.00000050.000000
1514990225.75626007100.0000005.0000007099.2000000.5500005.00000050.000000
1514990227.67164417100.0000005.0000007099.0000001.2000005.00000050.000000
1514990347.20807907200.0000005.0000007199.4000000.6500005.00000050.000000
1514990351.94564117200.0000005.0000007199.0000001.4000005.00000050.000000
1514993610.02344307300.0000005.0000007299.2000000.9500005.00000050.000000
1514993614.05316717300.0000005.0000007299.2000001.7500005.00000050.000000
1515045923.83729706900.0000005.0000006899.4000000.8000005.00000050.000000
1515045925.72866316900.0000005.0000006899.0000002.3500005.00000050.000000

P0=1014 mBar ⇒ P(170 m) =993 mBar , T= 293 ⇒ HV eff= HV app

La pression remonte

1017 mbar a 16h

A partir du run 738823 les PMs sont mieux alignes

7388196700830146 1.69 0.45 0.72 0.29 0.625.383
738820700028081489108153.03 0.9438.50 0.92 0.351.228
738821710070443133261.22 1.8447.16 1.88 0.171.257
7388237100155196275162.02 1.2348.42 1.27-0.011.098
7388247200125885272667.73 1.3257.71 1.39 0.201.265
738825730028582118187174.11 0.8265.47 0.89 0.251.406
7388266900191506617394734.55 0.3420.61 0.29 0.051.282
7388286800260743323416.61 0.73 8.98 0.56 0.221.259
7388317000166698571659.12 1.2042.98 1.21-0.191.012
73883271001587110390569.50 1.1657.03 1.24 0.081.111
738833720031023319275.16 2.4561.94 2.76 0.131.306
7388346700189110850 5.71 0.53 2.64 0.37-1.373.429

DAQ user 2018/01/04 10:57

7388297300/53001639105589064.37 1.1854.30 1.23 0.021.008
7388305300/730099161450861.96 1.5451.26 1.59-0.011.206

Le canal 1 (top) est tres bruyant (5x plus que le bottom)

On refait un point a 7000 V

1515060011.5218860-117000.0000005.0000006999.2000000.9000005.00000050.000000
1515060013.4772231-117000.0000005.0000006999.0000002.7500005.00000050.000000
1515066565.1403631-117100.0000005.0000007099.0000004.0000005.00000050.000000
1515066568.5592170-117100.0000005.0000007099.2000001.0000005.00000050.000000
1515070728.9142000-116700.0000005.0000006699.2000000.8000005.00000050.000000
1515070730.9515541-116700.0000005.0000006698.8000002.9000005.00000050.000000

Le courant sur le canal 1 explose a 7200 (4.5 micros), je redescend a 6700

La pression est tjs autour de 1013 mbar au niveau de la mer

On essaie la SY 1527 (lyoac28) (top = Low R cote etroit)

GAPBOTTOM │ 6700 V 55.0 uA 6706 V 0.9 uA On │00.0000
GAPTOP │ 6700 V 55.0 uA 6701 V 2.7 uA On │00.0001
738835670013594 6.67 2.15 2.96 1.46 6.2342.513
GAPBOTTOM │ 7200 V 8.0 uA 7207 V 1.2 uA On │00.0000
GAPTOP │ 7200 V 8.0 uA 7201 V 3.8 uA On │00.0001
738836720017012110571.18 3.4761.76 3.73-0.050.970

et apres 20 minutes

GAPBOTTOM │ 7200 V 8.0 uA 7207 V 1.2 uA On │00.0000
GAPTOP │ 7200 V 8.0 uA 7201 V 4.6 uA On │00.0001
738836720050237032873.71 1.9665.34 2.12 0.101.150
GAPBOTTOM │ 7300 V 8.0 uA 7307 V 1.6 uA On │00.0000
GAPTOP │ 7300 V 8.0 uA 7301 V 6.0 uA On │00.0001
738837730032122719970.72 2.5461.99 2.71 0.161.226

Ajout d'un troisieme scintillateur

1 mu / min

GAPBOTTOM    \u25027000   V    8.0 uA   7007 V    1.1 uA On                 \u250200.0000 
GAPTOP       \u2502  5000 V    8.0 uA   5001 V    0.7 uA On                 \u250200.0001 
7388407000/500072050935670.69 1.7049.44 1.86-0.140.652

DAQ user 2018/01/05 06:42

GAPBOTTOM \u2502 7000 V 8.0 uA 7007 V 1.1 uA On \u250200.0000
GAPTOP \u2502 7000 V 8.0 uA 7001 V 3.6 uA On \u250200.0001

Humidite constante 47 %

Pression Saint ex ⇒ P(0 m)= 1007 mbar

738841700025021317885.20 2.2571.20 2.86 0.022.827

Je remonte le 3 eme Scintillateur

GAPBOTTOM │ 7000 V 8.0 uA 7007 V 1.4 uA On │00.0000
GAPTOP │ 7000 V 8.0 uA 7001 V 4.3 uA On │00.0001

La fenetre est ouverte T ~ 18 C , H ~ 50 %

738842700053648537790.49 1.2770.34 1.97-0.250.624
GAPBOTTOM \u2502 7100 V 8.0 uA 7107 V 1.4 uA On \u250200.0000
GAPTOP \u2502 7100 V 8.0 uA 7101 V 5.0 uA On \u250200.0001
738843710035433528894.63 1.2081.36 2.07-0.220.680

On essaie un scan assymetrique

GAPBOTTOM \u2502 7200 V 8.0 uA 7207 V 1.7 uA On \u250200.0000
GAPTOP \u25026900 V 8.0 uA 6901 V 4.3 uA On \u250200.0001
7388447200/690016915813893.49 1.9081.66 2.98-0.080.874

pas evident d'en tirer quoi que ce soit

GAPBOTTOM \u2502 6900 V 8.0 uA 6906 V 1.3 uA On \u250200.0000
GAPTOP \u2502 6900 V 8.0 uA 6901 V 4.2 uA On \u250200.0001
73884767003672110 5.72 1.21 2.72 0.85-1.4010.311
7388466800170956326132.94 1.1415.27 0.87-0.580.604
738845690099366840267.27 1.4940.48 1.56-0.440.667
738842700053648537790.49 1.2770.34 1.97-0.250.624
738843710035433528894.63 1.2081.36 2.07-0.220.680
738844720016915813893.49 1.9081.66 2.98-0.080.874
738848730098895187996.26 0.6088.97 1.00-0.020.871

DAQ user 2018/01/06 09:30

Humidite 47 % T 18 C P 1004 mbar⇒ 984 mbar reel

⇒ HV app = HVeff

Le courant est trop eleve dans gap bottom (5 micros) je la mets a 1000 V

Scan avec channel 0 only

DAQ user 2018/01/07 09:58

P0(170 m) = 1010 hpa ⇒ P(170) =990 hPa , T=291 K H=47 %

738855670012143215 2.64 0.46 1.24 0.32 4.3742.033
7388536800550672612.18 1.39 4.73 0.90-1.572.939
7388526900114549626243.32 1.4622.88 1.24-0.510.582
738851700029771979140666.48 0.8747.23 0.91-0.360.670
738849710054845237382.48 1.6268.07 1.99-0.200.582
738850720046541937190.11 1.3879.78 1.86-0.100.664
738854730089880972690.09 1.0080.85 1.31-0.120.676
738856740039637235293.94 1.2088.89 1.58 0.030.654

DAQ user 2018/01/07 19:05

P0(170 m) = 1012 hpa ⇒ P(170) =992 hPa , T=291 K H=47 %

Fig. 1: Efficiency of one gap with TFE/CO2/SF6 in blue, in orange is the calculated efficiency with 2 gaps

La precision sur HV eff depend de la pression , la temperature est restee stable a 18 C

P0(170 m) = 1007 +- 5 mBar

⇒ P a varie de 983 mBar a 993 mBar

⇒ On obtient un facteur $\alpha$ entre 0.2 pour mille et 8 pour mille, donc une variation maximale de 60 V entre les differents points

Noise study

Run HV Rate on FEB (Hz) Rate on Channels (Hz)
738858 2000 638 27
7388556700 789 34
7388536800 885 38
7388526900 907 39
7388517000 2128 92
73884971003645158
73885072002348102
7388547300157168
73885674002601113

Humidity studies

On stoppe le passage dans le tonneau

P0(170 m) = 1013 mBar

Apres 2 h — DAQ user 2018/01/09 14:15

GAPBOTTOM 2004 0.0
GAPTOP 2000 0.0
GAPBOTTOM 4006 0.1
GAPTOP 4001 0.1
GAPBOTTOM 5006 0.1
GAPTOP 5002 0.3
GAPBOTTOM 5507 0.1
GAPTOP 5501 0.5
Honeywell

46.801367 17.702661 Tue Jan 9 14:34:29 2018

 Chan       VSET       ISET       VOUT       IOUT     RAMPUP     STATUS 
#0000    5500.00       8.00    5507.00       0.10       5.00          1 
#0001    5500.00       8.00    5502.00       0.50       5.00          1 

#0000    6000.00       8.00    6007.00       0.20       5.00          1 
#0001    6000.00       8.00    6002.00       0.90       5.00          1 

#0000    6000.00       8.00    6007.00       0.30       5.00          1 
#0001    6000.00       8.00    6002.00       0.90       5.00          1 

#0000    6300.00       8.00    6306.00       0.60       5.00          1 
#0001    6300.00       8.00    6302.00       1.30       5.00          1 

46.752533 17.883958 Tue Jan  9 15:04:49 2018

#0000    6500.00       8.00    6507.00       0.70       5.00          1 
#0001    6500.00       8.00    6503.00       1.80       5.00          1 


46.361861 18.296911 Tue Jan  9 15:45:19 2018

#0000    6500.00       8.00    6507.00       0.60       5.00          1 
#0001    6500.00       8.00    6503.00       1.80       5.00          1 

#0000    6700.00       8.00    6707.00       0.90       5.00          1 
#0001    6700.00       8.00    6703.00       2.30       5.00          1 


46.825784 17.924246 Tue Jan  9 16:03:55 2018

#0000    6700.00       8.00    6707.00       0.90       5.00          1 
#0001    6700.00       8.00    6703.00       2.40       5.00          1 


47.246978 17.924246 Tue Jan  9 16:23:55 2018

#0000    6700.00       8.00    6707.00       0.80       5.00          1 
#0001    6700.00       8.00    6703.00       2.40       5.00          1 


47.198144 17.994750 Tue Jan  9 16:27:08 2018

#0000    6800.00       8.00    6807.00       0.80       5.00          1 
#0001    6800.00       8.00    6802.00       2.70       5.00          1 

Trop de bruit sur channel 1 (TOP)

#0000    6900.00       8.00    6906.00       1.00       5.00          1 
#0001    5800.00       8.00    5802.00       0.90       5.00          1 

On coupe la tension et on envoie le gaz directement sur la sonde