This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
nouvelle_mesure_impedance_lyon [2017/12/19 10:05] acqilc [Mesure au LC metre] |
nouvelle_mesure_impedance_lyon [2021/07/10 23:21] (current) |
||
---|---|---|---|
Line 52: | Line 52: | ||
===== injection 5V methode des plateaux ===== | ===== injection 5V methode des plateaux ===== | ||
- | $V_s = 4.48 $ V | + | ==== Cote Large ==== |
+ | $V_s = 4.54 $ V | ||
- | => $Z_c = \frac{50 \times V_s}{10 - V_s}= 41 \Omega $ | + | => $Z_c = \frac{50 \times V_s}{10 - V_s}= 42 \Omega $ |
===== injection 5V methode du potentiometre ===== | ===== injection 5V methode du potentiometre ===== | ||
- | => $R_{potentiometre} = 46 \Omega $ | + | => $R_{potentiometre} = 43 \Omega $ |
Line 81: | Line 82: | ||
^ injection ^ Transmis ^ rebond ^ dt injection transmis ^ dt inejction rebond ^ Fall injection ^Fall transmis ^ | ^ injection ^ Transmis ^ rebond ^ dt injection transmis ^ dt inejction rebond ^ Fall injection ^Fall transmis ^ | ||
- | | -39.6 | -30.5 | + 6.3 | 9.65 ns |18.35 |2.65 ns | 2.90 ns | | + | | -39.0 | -30.0 | + 6.2 | 8.40 ns |18.2 |2.60 ns | 3.40 ns | |
====== Cassette __Sans HV__ ====== | ====== Cassette __Sans HV__ ====== |