User Tools

Site Tools


calibration_des_boards_fe_4_et_fe_2

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
calibration_des_boards_fe_4_et_fe_2 [2017/11/26 10:48]
mirabito [Resistance 150 kOhm]
calibration_des_boards_fe_4_et_fe_2 [2021/07/10 23:21] (current)
Line 179: Line 179:
  
 == Etude de l'​efficacité == == Etude de l'​efficacité ==
 +
 +Seuil a **343**
 +
 +**(343-327)/​0.139 =115 fC /2 => 57.5 fC par canal**
  
 ^ run ^ Injection(fC) ^ N trg ^ N 2 ^ N 14 ^ Eff ^ deFF ^ Eff XY ^ deff XY ^ $\Delta T $(ns)  ^ $\sigma $ dt (ns) ^ ^ run ^ Injection(fC) ^ N trg ^ N 2 ^ N 14 ^ Eff ^ deFF ^ Eff XY ^ deff XY ^ $\Delta T $(ns)  ^ $\sigma $ dt (ns) ^
Line 201: Line 205:
 </​imgcaption>​ </​imgcaption>​
  
---- //​[[laurent.mirabito@gmail.com|mirabito]] 2017/11/21 06:48//+ --- //​[[laurent.mirabito@gmail.com|mirabito]] 2017/11/26 15:40//
  
 ===== Calibration Board 2 ===== ===== Calibration Board 2 =====
  
-==== Resistqnce ​100 kOhm ===+==== Resistance ​100 kOhm ===
 === Pedestal === === Pedestal ===
  
Line 314: Line 318:
  
 </​imgcaption>​ </​imgcaption>​
-On met le seuil a 494+ 
 +On met le seuil a **494** 
 + 
 +**(494-471)/​0.1845 = 125 fC /2 => 62.5 fC de seuil par canal** 
  
 ^ run ^ Injection(fC) ^ N trg ^ N 2 ^ N 14 ^ Eff ^ deFF ^ Eff XY ^ deff XY ^ dt (ns)  ^ RMS dt (ns) ^ ^ run ^ Injection(fC) ^ N trg ^ N 2 ^ N 14 ^ Eff ^ deFF ^ Eff XY ^ deff XY ^ dt (ns)  ^ RMS dt (ns) ^
Line 356: Line 364:
  
  --- //​[[laurent.mirabito@gmail.com|mirabito]] 2017/11/23 06:35//  --- //​[[laurent.mirabito@gmail.com|mirabito]] 2017/11/23 06:35//
 + --- //​[[laurent.mirabito@gmail.com|DAQ user]] 2017/11/27 12:12//
  
calibration_des_boards_fe_4_et_fe_2.1511693291.txt.gz · Last modified: 2021/07/10 23:20 (external edit)