4 Febs on lyocmsrpi02,03,04,05
Firmware version 20042018_17:00
Channel 23 is now connected to PETIROC input 19 (from 0) instead of 11
Database version is FE1_24CH_30 (all DAC6B from 11 to 19 are set to 31)
— DAQ user 2018/04/25 22:09
Run 740010 calibration all together (really noisy) Q: is there any HV ?
Run 740011 calibration strip by strip on going
— DAQ user 2018/04/26 09:02
Mistake in the configuration the state was FE1_24CH_27 instead of 30
Calibration repeated with
daqcontrol --daq-downloaddb ----dbstate=FE1_24CH_30
New run one/one 740016
— DAQ user 2018/04/26 11:31
Ok a bit noisy but the mapping is wrong we lost completly the strip 12. We switch back to previous mapping
— DAQ user 2018/04/26 16:39
Christophe added ground and trigger cables
firmware with old coax mapping
pedestal run all togeher : 740108
VTH cut = 507
Physics run:
— DAQ user 2018/04/26 16:43
WEBDCS is playing with HV I go back to Lyon
Run | HV | Mode | N event | N trigger | rate 6 |
---|---|---|---|---|---|
740113 | 1000/6000 | ILC | 142388 | 2970 | 400 |
— DAQ user 2018/04/27 14:43
Le nouveau firmware ne marche pas on revient sur TDC_DAQ_24CH_CLK
daqcontrol --daq-download --dbstate=FE1_24CH_30 daqcontrol --daq-setvth --vth=507 daqcontrol --daq-configure daqcontrol --trig-spillof --clock=10000 daqcontrol --trig-spillon --clock=100000 daqcontrol --trig-spillreg --value=2 daqcontrol --trig-setreg --address=7 --value=160000000