====== Installation and commissioning of cable chamber ====== ===== Geometry ===== Four FEBs intsalled from external to middle: * TDC 5, First serie, strip 1-12 * TDC 8, Second serie, strip 13-24, * TDC 6, second serie, strip 25-36 * TDC 7, second serie, strip 37-48 Each of it is reading 12 strips both side. The mapping of the 12 strips is the following: ^Strip ^ TDC channel High Radius ^ TDC channel Low Radius ^ |1| 10 |14| |2| 6 |11| |3| 2 |7| |4| 0 |3| |5| 4 |1| |6| 8 |5| |7| 12 |9| |8| 16 |13| |9| 18 |15| |10| 20 |17| |11| 22 |19| |12| missing (23) |21| The channel 23 is not connected to a lemo in the current version of firmware. Upgrade version of firmware with the correct connection will require a new calibration of Petirocs DAC ===== Pedestals ===== --- //[[laurent.mirabito@gmail.com|DAQ user]] 2018/04/02 11:03// Run 739605,606 and 607 were done to align all pedestal to VThTime @ 480 The settings for starting a run are: # 4 FEBS aligned 491+15 daqcontrol --daq-download --dbstate=FE1_24CH_29 daqcontrol --daq-setvth --vth=506 daqcontrol --daq-configure daqcontrol --trig-spillof --clock=10000 daqcontrol --trig-spillon --clock=100000 # 499 for TDC5 and 494 for TDC8 in DB #daqcontrol --daq-setvth --vth=500 daqcontrol --trig-spillreg --value=4