nouvelle_mesure_pcb_fin_cern [2017/12/18 09:46]
acqilc [Measured distance at different HV applied]
nouvelle_mesure_pcb_fin_cern [2021/07/10 23:21] (current)
Line 171: Line 171:
  
 ===== New analysis ===== ===== New analysis =====
 +==== Efficiency studies ====
 +
 ^Run ^ HV applied ^ HV eff ^  N trigger ^ N strip ^ N 2 Strip ^ $\epsilon$ (%) ^ d$\epsilon$ ^$\epsilon_2$ (%) ^ d$\epsilon_2$ ^ <$\Delta T $> ^ $\sigma \Delta T$ ^ ^Run ^ HV applied ^ HV eff ^  N trigger ^ N strip ^ N 2 Strip ^ $\epsilon$ (%) ^ d$\epsilon$ ^$\epsilon_2$ (%) ^ d$\epsilon_2$ ^ <$\Delta T $> ^ $\sigma \Delta T$ ^
 |738747|6600|6832|1077|405|263|37.60| 1.48|24.42| 1.31|-0.59|0.653| |738747|6600|6832|1077|405|263|37.60| 1.48|24.42| 1.31|-0.59|0.653|
Line 183: Line 185:
  
  
 +<​imgcaption cern_eff_hveffn| Efficiency curve from previous runs in function of effective HV. Blue is strip efficiency, yellow (X,Y) efficiency >
 {{ :​cern_dec_2017:​scan_cern_newananlys.png |}} {{ :​cern_dec_2017:​scan_cern_newananlys.png |}}
 +</​imgcaption>​
  
 ==== Measured distance at different HV applied==== ==== Measured distance at different HV applied====
nouvelle_mesure_pcb_fin_cern.1513590379.txt.gz ยท Last modified: 2021/07/10 23:20 (external edit)