===== New analysis ===== | ===== New analysis ===== | ||
+ | ==== Efficiency studies ==== | ||
+ | |||
^Run ^ HV applied ^ HV eff ^ N trigger ^ N strip ^ N 2 Strip ^ $\epsilon$ (%) ^ d$\epsilon$ ^$\epsilon_2$ (%) ^ d$\epsilon_2$ ^ <$\Delta T $> ^ $\sigma \Delta T$ ^ | ^Run ^ HV applied ^ HV eff ^ N trigger ^ N strip ^ N 2 Strip ^ $\epsilon$ (%) ^ d$\epsilon$ ^$\epsilon_2$ (%) ^ d$\epsilon_2$ ^ <$\Delta T $> ^ $\sigma \Delta T$ ^ | ||
|738747|6600|6832|1077|405|263|37.60| 1.48|24.42| 1.31|-0.59|0.653| | |738747|6600|6832|1077|405|263|37.60| 1.48|24.42| 1.31|-0.59|0.653| | ||
Line 183: | Line 185: | ||
+ | <imgcaption cern_eff_hveffn| Efficiency curve from previous runs in function of effective HV. Blue is strip efficiency, yellow (X,Y) efficiency > | ||
{{ :cern_dec_2017:scan_cern_newananlys.png |}} | {{ :cern_dec_2017:scan_cern_newananlys.png |}} | ||
+ | </imgcaption> | ||
==== Measured distance at different HV applied==== | ==== Measured distance at different HV applied==== |