nouvelle_mesure_impedance_lyon [2017/12/18 13:54]
acqilc [injection 5V methode des plateaux]
nouvelle_mesure_impedance_lyon [2021/07/10 23:21] (current)
Line 48: Line 48:
 |2000|Large|167|116|596|800|60| |2000|Large|167|116|596|800|60|
  
-====== Cassette ======+====== Cassette ​ 100 V  ====== 
 + 
 +===== injection 5V methode des plateaux ===== 
 + 
 +==== Cote Large ==== 
 +$V_s = 4.54 $ V 
 + 
 +=>  $Z_c = \frac{50 \times V_s}{10 - V_s}= 42 \Omega $ 
 + 
 +===== injection 5V methode du potentiometre ===== 
 + 
 +=> $R_{potentiometre} = 43 \Omega $ 
 + 
 + 
 +===== Mesure au LC metre ===== 
 + 
 +^ Frequence (kHz)^ Cote ^ Cp (pF) ^ Gp $\mu$S ^ Ls (nH) ^ Rs (m$\Omega)$ ^ Zc ($\Omega$)^ 
 +|1|Large|574|0.157|723|273|275| 
 +|10|Large|622|6.4|577|275|84| 
 +|100|Large|450|63|541|292|39| 
 +|500|Large|337|342|503|362|38.2| 
 +|1000|Large|284|600|492|416|38.6| 
 +|2000|Large|244|934|482|467|43.5| 
 +|1|Etroit| 595|0.170|720| 275|271| 
 +|10|Etroit| 620|6.4|583| 277|84| 
 +|100|Etroit| 450|62|547| 294|40| 
 +|500|Etroit| 337|344|510| 362|38| 
 +|1000|Etroit| 284|600|499| 414|41| 
 +|2000|Etroit| 244|934|487| 461|44| 
 + 
 +  
 +===== Injection 5 PC ===== 
 + 
 +^ injection ^ Transmis ^ rebond ^ dt injection transmis ^ dt inejction rebond ^ Fall injection ^Fall transmis ^ 
 +| -39.0 | -30.0  | + 6.2 | 8.40 ns |18.2 |2.60 ns | 3.40 ns | 
 + 
 +====== Cassette ​ __Sans HV__ ======
  
 ===== injection 5V methode des plateaux ===== ===== injection 5V methode des plateaux =====
Line 64: Line 100:
  
 ^ Frequence (kHz)^ Cote ^ Cp (pF) ^ Gp $\mu$S ^ Ls (nH) ^ Rs (m$\Omega)$ ^ Zc ($\Omega$)^ ^ Frequence (kHz)^ Cote ^ Cp (pF) ^ Gp $\mu$S ^ Ls (nH) ^ Rs (m$\Omega)$ ^ Zc ($\Omega$)^
-|2000|Large|215|131|416|1930|44+|1|Large|673|0.189|719|273|254| 
-|2000|Etroit| ​205|99|390975|44|+|100|Large|445|62|543|292|40| 
 +|1000|Large|292|634|483|396|40| 
 +|2000|Large|300|1300|430|267|37| 
 +|1|Etroit| 700|0.2|705| 274|249| 
 +|10|Etroit| 1300|13.7|584| 276|58| 
 +|100|Etroit| 447|61|546| 292|40| 
 +|500|Etroit| 336|342|507| 363|38| 
 +|1000|Etroit| 280|600|494410|41
 +|2000|Etroit| ​242|916|482420|44|
  
    
 +===== Injection 5 PC =====
  
 +^ injection ^ Transmis ^ rebond ^ dt injection transmis ^ dt inejction rebond ^ Fall injection ^Fall transmis ^
 +| -39.6 | -30.5  | + 6.3 | 9.65 ns |18.35 |2.65 ns | 2.90 ns |
nouvelle_mesure_impedance_lyon.1513605254.txt.gz · Last modified: 2021/07/10 23:20 (external edit)