User Tools

Site Tools


debug_febv1_1

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
debug_febv1_1 [2019/03/13 06:23]
acqilc [Mapping correct pour 32 cannaux]
debug_febv1_1 [2021/07/10 23:21] (current)
Line 108: Line 108:
 ===== Piedestaux ===== ===== Piedestaux =====
  
-**HV = 500 V +
-**+
  
 ==== By channel ==== ==== By channel ====
 +
 +**HV = 500 V **
  
 |747979|FEB_1112_2|FEB_1112_6| |747979|FEB_1112_2|FEB_1112_6|
 |747981|FEB_1112_6|FEB_1112_7| |747981|FEB_1112_6|FEB_1112_7|
 |747983|FEB_1112_7|**FEB_1112_8**| |747983|FEB_1112_7|**FEB_1112_8**|
 +|747984|FEB_1112_8| Step 2|
 +
 +{{ :​mars2019:​run747984_allstrip11_1.png?​400 |}}
 +{{ :​mars2019:​run747984_allstrip11_2.png?​400 |}}
 +{{ :​mars2019:​run747984_allstrip12_1.png?​400 |}}
 +{{ :​mars2019:​run747984_allstrip12_2.png?​400 |}}
 +
 +==== All strips ====
 +
 +**HV = 7200 V **
 +
 +Pedestal 747986
 +
 +Physics: 747985, seuil 505, Spillon 8000, SPill off=1000, ​ Active =3 (40 ns) Dead=3 (20 ns)
 +
 +{{ :​mars2019:​run747986_allstrip11_1.png?​400 |}}
 +{{ :​mars2019:​run747986_allstrip11_2.png?​400 |}}
 +{{ :​mars2019:​run747986_allstrip12_1.png?​400 |}}
 +{{ :​mars2019:​run747986_allstrip12_2.png?​400 |}}
 +
 +==== Runs with cosmic stand ====
 +
 +We use large scintillators and a FEB config with 48 strips. 2 FEBS are using covering 1/2 of the chamber
  
 +Config FEB_1112_9. Spillon 8000, SPill off=1000, ​ Active =3 (40 ns) Dead=3 (20 ns)
 +Threshold 500. 
  
 +|Run|HVapp|Thr|
 +|748030|7000|500|
 +|748031|7200|500|
 +|748032|7400|500|
 +|748034|7600|500|
 +|748035|6800|500|
 +|------|----|---|
 +|748034|7600|510|
  
debug_febv1_1.1552458239.txt.gz · Last modified: 2021/07/10 23:20 (external edit)